Skip to main content
9 events
when toggle format what by license comment
Oct 25, 2019 at 16:23 comment added S'Danc @MattL., yeah, I didn't know linear phase FIR filters had the reciprocal rule for zeros until someone commented it. It was pretty straightforward once I learned that.
Oct 25, 2019 at 16:03 comment added Matt L. @S'Danc: Yes, filter length = no. of coefficients = order + 1. But with the given information, do you manage to come up with 10 zeros?
Oct 25, 2019 at 15:14 comment added S'Danc @MattL. it is order 10. Just so I understand what you're talking about for exam prep, if it has 10 zeros, shouldn't it have 11 coefficients and be of order 10? Would that make the length 11?
Oct 25, 2019 at 15:11 vote accept S'Danc
Oct 25, 2019 at 8:02 answer added Richard Lyons timeline score: 2
Oct 25, 2019 at 6:48 comment added Matt L. Are you sure it's order $10$, not length $10$ (i.e., $10$ filter coefficients)?
Oct 25, 2019 at 6:47 history edited Matt L. CC BY-SA 4.0
deleted 21 characters in body
Oct 25, 2019 at 2:59 comment added Dan Boschen I don't want to give you the complete answer since this looks like an obvious homework or test question, but certainly want to help. I believe the question is checking if you understand a well documented characteristic of the placement of zeros for a LINEAR PHASE filter. It may help if you understand the zero placement for MINIMUM PHASE and MAXIMUM PHASE filters as well, and the difference between all three filters. (I hope that was enough hints on what to dig into)
Oct 25, 2019 at 2:03 history asked S'Danc CC BY-SA 4.0