Source Link

Quality factor of RLC circuit

I am trying to calculate the quality factor for the response curve of a series RLC circuit. I measured the voltage across the capacitor at several frequencies and calculated its ratio to the forcing voltage. The curve I obtained is as follows: enter image description here

How is it possible to find quality factor when there no points where the curve reach -3db on the left side of the peak?